NIOSH logo and tagline

Ferbam

Synonyms & Trade Names
tris(Dimethyldithiocarbamato)iron, Ferric dimethyl dithiocarbamate
CAS No.
14484-64-1
RTECS No.
DOT ID & Guide
Formula
[(CH₃)₂NCS₂]₃Fe
Conversion
IDLH
800 mg/m3
See: 14484641
Exposure Limits
NIOSH REL
TWA 10 mg/m3
OSHA PEL
TWA 15 mg/m3 See Appendix G
Measurement Methods
NIOSH 0500
See: NMAM or OSHA Methods
Physical Description
Dark brown to black, odorless solid. [fungicide]
Molecular Weight
416.5
Boiling Point
Decomposes
Melting Point
>356°F (Decomposes)
Solubility
0.01%
Vapor Pressure
0 mmHg (approx)
Ionization Potential
7.72 eV
Specific Gravity
?
Flash Point
?
Upper Explosive Limit
?
Lower Explosive Limit
?
Minimum Explosive Concentration
55 g/m3
Combustible Solid
Incompatibilities & Reactivities
Strong oxidizers, moisture
Exposure Routes
inhalation, ingestion, skin and/or eye contact
Symptoms
irritation eyes, resp tract; dermatitis; gastrointestinal disturbance
Target Organs
Eyes, skin, respiratory system, gastrointestinal tract
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

Up to 50 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.

Up to 100 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.*
(APF = 10) Any supplied-air respirator*

Up to 250 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.*

Up to 500 mg/m3:


(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters. 


(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode*
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 800 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:


(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters. 


Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 0792
Page last reviewed: October 30, 2019