NIOSH logo and tagline

N-Phenyl-β-naphthylamine

Synonyms & Trade Names
2-Anilinonaphthalene, β-Naphthylphenylamine, PBNA, 2-Phenylaminonaphthalene, Phenyl-β-naphthylamine
CAS No.
135-88-6
RTECS No.
DOT ID & Guide
Formula
C₁₀H₇NHC₆H₅
Conversion
IDLH
Ca [N.D.]
See: IDLH INDEX
Exposure Limits
NIOSH REL
Ca* See Appendix A [*Note: Since metabolized to β-Naphthylamine.]
OSHA PEL
none
Measurement Methods
OSHA 96
See: NMAM or OSHA Methods
Physical Description
White to yellow crystals or gray to tan flakes or powder. [Note: Commercial product may contain 20-30 ppm of β-Naphthylamine.]
Molecular Weight
219.3
Boiling Point
743°F
Melting Point
226°F
Solubility
Insoluble
Vapor Pressure
?
Ionization Potential
?
Specific Gravity
1.24
Flash Point
?
Upper Explosive Limit
?
Lower Explosive Limit
?
Combustible Solid
Incompatibilities & Reactivities
Oxidizers
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms
Irritation; leucoplakia; acne, hypersensitivity to sunlight; [potential occupational carcinogen]
Target Organs
Eyes, skin, bladder
Cancer Site
[bladder cancer]
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated/Daily
Remove:When wet or contaminated
Change:Daily
Provide:Eyewash, Quick drench
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

At concentrations above the NIOSH REL, or where there is no REL, at any detectable concentration:


(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 0542
Page last reviewed: October 30, 2019