Sepsis Attributed to Bacterial Contamination of Platelets Associated with a Potential Common Source — Multiple States, 2018
Weekly / June 14, 2019 / 68(23);519–523
Sydney A. Jones, PhD1,2; Jefferson M. Jones, MD3; Vivian Leung, MD2; Allyn K. Nakashima, MD4; Kelly F. Oakeson, PhD5; Amanda R. Smith, PhD4; Robert Hunter, MS6; Janice J. Kim, MD6; Melissa Cumming, MS7; Eileen McHale7; Pampee P. Young, MD, PhD8; Joy L. Fridey, MD9; Walter E. Kelley, DO10; Susan L. Stramer, PhD11; Stephen J. Wagner, PhD12; F. Bernadette West, MD13; Ross Herron, MD9; Edward Snyder, MD14; Jeanne E. Hendrickson, MD14; David R. Peaper, MD, PhD14; Adi V. Gundlapalli, MD, PhD15,16; Charles Langelier, MD, PhD17,18; Steve Miller, MD, PhD17; Ashok Nambiar, MD17; Morvarid Moayeri, MD, PhD17; Jack Kamm, PhD18; Heather Moulton-Meissner, PhD3; Pallavi Annambhotla, DrPH3; Paige Gable3; Gillian A. McAllister3; Erin Breaker, MS3,19; Erisa Sula, MS3,19; Alison Laufer Halpin, PhD3; Sridhar V. Basavaraju, MD3 (View author affiliations)
View suggested citationSummary
What is already known about this topic?
Bacterial contamination of platelets is rare (approximately one in 5,000 platelet units) but poses serious risk to platelet transfusion recipients.
What is added by this report?
Sepsis resulting from bacterial contamination of platelets can occur even with implementation of bacterial mitigation strategies. Whole genome sequencing indicated a potential common source of bacterial contamination among four cases of septic transfusion reactions occurring in three states.
What are the implications for public health practice?
Clinicians need to monitor for sepsis after platelet transfusions even after implementation of bacterial mitigation strategies and immediately report adverse reactions to platelet suppliers and hemovigilance systems.
During May–October 2018, four patients from three states experienced sepsis after transfusion of apheresis platelets contaminated with Acinetobacter calcoaceticus-baumannii complex (ACBC) and Staphylococcus saprophyticus; one patient died. ACBC isolates from patients’ blood, transfused platelet residuals, and two environmental samples were closely related by whole genome sequencing. S. saprophyticus isolates from two patients’ blood, three transfused platelet residuals, and one hospital environmental sample formed two whole genome sequencing clusters. This whole genome sequencing analysis indicated a potential common source of bacterial contamination; investigation into the contamination source continues. All platelet donations were collected using apheresis cell separator machines and collection sets from the same manufacturer; two of three collection sets were from the same lot. One implicated platelet unit had been treated with pathogen-inactivation technology, and two had tested negative with a rapid bacterial detection device after negative primary culture. Because platelets are usually stored at room temperature, bacteria in contaminated platelet units can proliferate to clinically relevant levels by the time of transfusion. Clinicians should monitor for sepsis after platelet transfusions even after implementation of bacterial contamination mitigation strategies. Recognizing adverse transfusion reactions and reporting to the platelet supplier and hemovigilance systems is crucial for public health practitioners to detect and prevent sepsis associated with contaminated platelets.
Investigation and Results
California. On May 4, a male patient with acute lymphoblastic leukemia (patient A) received pathogen-reduced apheresis platelets at hospital A in California (Figure). Within minutes of completing the transfusion, he briefly experienced rigors, followed 2 hours later by fever and hypotension. He was transferred to the intensive care unit for management of septic shock and recovered fully. Posttransfusion patient blood cultures (obtained 2 hours after vancomycin administration) grew only ACBC. Gram stain of the implicated platelet bag residual revealed gram-positive cocci in pairs or chains; culture of the platelet bag residual grew ACBC and S. saprophyticus. The implicated platelet unit was one of two platelet units manufactured from a single apheresis donation collected 5 days earlier in California. Pathogen inactivation was performed 13.5 hours after collection. Hospital A located the second platelet unit (which had not been transfused), quarantined it, and notified the blood supplier. Gram stain and culture of this platelet unit were negative. Samples obtained from the donor’s skin were culture-negative for ACBC and S. saprophyticus. Environmental samples obtained weeks later from the platelet collection facility and hospital A yielded no relevant organisms; however, sampled areas had been cleaned in the interim.
Utah. On May 10, a male patient with cirrhosis and thrombocytopenia (patient B) received a platelet transfusion at hospital B to prevent bleeding before a procedure (Figure). One hour after transfusion began, patient B complained of chills, and the transfusion was terminated. Two hours after transfusion, he became febrile, hypotensive, and tachypneic, and antibiotics were started; he died of septic shock 2 days later. ACBC was isolated by culture from platelet bag residuals and posttransfusion blood samples from the patient. The platelet supplier was notified, and a second platelet unit manufactured from the same apheresis donation, which had not been transfused, was recalled. The platelet supplier performed primary aerobic culture of the implicated donation for bacterial contamination 24 hours after collection in Utah; the primary culture remained negative after 5 days. The implicated platelet unit was transfused 5 days after collection. Samples obtained on May 24 from the donor’s urine, perianal area, and multiple skin sites screened negative for ACBC colonization. Samples obtained from platelet agitators at the platelet manufacturing facility (May 23) and hospital B (June 7) yielded ACBC isolates.
Connecticut and Massachusetts. On October 4, at hospital C, two male patients with acute myeloid leukemia (patients C and D) each received a platelet unit manufactured from a common apheresis donation (Figure). Within two hours of transfusion, both patients became hypotensive and febrile. Both were transferred to the intensive care unit, and both recovered. ACBC and S. saprophyticus were isolated by culture from posttransfusion blood samples from both patients and from both platelet bag residuals. Hospital C notified the platelet supplier. The implicated apheresis platelet donation had been collected in Massachusetts 4 days before transfusion and processed in Connecticut. Twenty-four hours after collection, the platelet supplier performed primary aerobic and anaerobic culture for bacterial contamination. Within 5 hours before transfusion, hospital C screened both platelet units with a rapid bacterial detection device; all tests were negative. No ACBC or S. saprophyticus isolates were identified among environmental swabs collected at platelet supplier facilities in Connecticut (November 15) and Massachusetts (November 16); S. saprophyticus was isolated from one platelet agitator at hospital C on November 13.
Multistate investigation. On July 17, notices were issued through CDC’s Epi-X and the Infectious Diseases Society of America’s Emerging Infections Network to identify additional cases of sepsis caused by Acinetobacter infections with onset of symptoms within 24 hours after platelet transfusion. Three cases were reported from two states (North Carolina [patients E and F] and Michigan [patient G]).
Traceback investigation revealed that the three platelet donations implicated in the California, Utah, and Connecticut septic transfusion reactions (i.e., sepsis attributed to transfusion) were from different donors. The donors in California, Utah, and Massachusetts had no known epidemiologic links to one another and no symptoms suggesting bacteremia or illness; all were indefinitely deferred. All three apheresis donations were collected in platelet additive solution using apheresis cell separator machines and collection sets from the same manufacturer; two of three collection sets were from a single lot.
CDC performed whole genome sequencing on collected ACBC and S. saprophyticus isolates (Table) using standard methods (1). ACBC organisms were isolated by culture from posttransfusion blood samples from patients A, B, C, and D; all four associated transfused platelet bag residuals; and environmental samples from hospital B and the platelet supplier in Utah. Fourteen ACBC isolates from these sources were highly related (differing by 0–32 single nucleotide polymorphisms [SNPs] across a 95.6% core genome) (Supplementary Figure 1, https://stacks.cdc.gov/view/cdc/78727) and appear to represent a novel ACBC taxon (only 90% match to Acinetobacter seifertii by average nucleotide identity). In contrast, ACBC isolates from cases in North Carolina and Michigan were not closely related to isolates from cases in California, Utah, and Connecticut by whole genome sequencing (differing by 13,398–14,289 SNPs across a 30.5% core genome).
S. saprophyticus was isolated by culture from posttransfusion blood samples from patients C and D; transfused platelet bag residuals from patients A, C, and D; and an environmental sample from hospital C (Table). Whole genome sequencing analysis revealed two clusters of S. saprophyticus isolates. One cluster consisted of S. saprophyticus isolates from patient C’s blood, patient C’s platelet bag residual, and an environmental swab from hospital C (differing by 0–37 SNPs across a 94.9% core genome) (Supplementary Figure 2, https://stacks.cdc.gov/view/cdc/78728); the second cluster consisted of isolates from patient D’s blood and from patient D’s and patient A’s platelet bag residuals (difference of 1–27 SNPs across a 94.9% core genome).
Discussion
Transfusion of platelets is more likely to result in sepsis than is transfusion of other blood products; data derived from primary cultures have indicated that approximately one in every 5,000 platelet collections is contaminated with bacteria (2). ACBC is not frequently reported as a contaminant of platelets (3). ACBC consists of gram-negative bacilli that commonly occur in wet environments and are opportunistic pathogens; ACBC organisms are resistant to desiccation, persist on environmental surfaces, and avidly adhere to plastics (4). Conversely, coagulase-negative Staphylococcus spp. are among the most common bacterial contaminants of platelets (3,5). However, S. saprophyticus might be less likely to contaminate platelets than other coagulase-negative Staphylococcus spp. because it typically resides in the gastrointestinal and urinary tracts rather than on the skin (6).
Whole genome sequencing analysis indicated an unidentified potential common source of bacterial contamination among the four cases of septic transfusion reactions reported here. Investigation into the contamination source continues. Although skin microflora and donor bacteremia are the most frequent sources of bacterial contamination (7), a cluster of septic transfusion reactions attributed to contamination of blood collection bags during manufacturing or packaging was reported in 1993 (8).
Food and Drug Administration regulations state that blood establishments and transfusion services must assure adequate control of the risk for bacterial contamination of platelets.* Most U.S. blood suppliers fulfill this requirement by performing a primary culture of platelet donations before transfusion (2). Because the risk for platelet transfusion–associated sepsis has persisted despite implementation of primary cultures, additional bacterial mitigation strategies have been implemented, including pathogen-inactivation technology, rapid bacterial detection devices, and alternative culture strategies (2). This report underscores the possibility that sepsis resulting from bacterial contamination of platelets can occur even with application of bacterial contamination mitigation strategies.
The consequences of septic transfusion reactions are often severe morbidity or mortality. In the cluster reported here, one of four patients died, and three recovered only after receiving intensive care. Even with implementation of bacterial contamination mitigation strategies, clinicians should continue to monitor recipients for sepsis after platelet transfusions and immediately report adverse reactions to the platelet supplier and hemovigilance systems.
Corresponding author: Sydney A. Jones, okn7@cdc.gov, 860-509-7995.
1Epidemic Intelligence Service, CDC; 2Connecticut Department of Public Health; 3Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, CDC; 4Utah Department of Health; 5Utah Public Health Laboratory, Taylorsville, Utah; 6California Department of Public Health; 7Massachusetts Department of Public Health; 8American Red Cross Blood Services National Headquarters, Washington, DC; 9American Red Cross Blood Services, Pomona, California; 10American Red Cross Blood Services, Salt Lake City, Utah; 11Scientific Affairs, American Red Cross, Gaithersburg, Maryland; 12Transfusion Innovation, American Red Cross, Rockville, Maryland; 13American Red Cross Blood Services, Farmington, Connecticut; 14Yale University, New Haven, Connecticut; 15VA Salt Lake City Health Care System, Salt Lake City, Utah; 16University of Utah School of Medicine, Salt Lake City; 17University of California, San Francisco; 18Chan Zuckerberg Biohub, San Francisco, California; 19Oak Ridge Associated Universities, Oak Ridge, Tennessee.
All authors have completed and submitted the ICMJE form for disclosure of potential conflicts of interest. David Peaper reports equity in and service on the advisory board of Tangen Biosciences; F. Bernadette West was a principal investigator for previous Cerus Corporation studies; Edward Snyder was the principal investigator on two grants from Cerus Corporation to Yale University to conduct PIPER, a Phase IV post-market study of pathogen-reduced platelets, and ReCePI, a randomized controlled trial of pathogen-reduced red cells, (no personal remuneration received for either study); Stephen Wagner reports personal fees from bioMérieux outside the submitted work. No other potential conflicts of interest were disclosed.
* Food and Drug Administration. Control of Bacterial Contamination of Platelets, 21 CFR Section 606.145, 2017. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/CFRSearch.cfm?fr=606.145.
References
- Shenoy ES, Pierce VM, Walters MS, et al. Transmission of mobile colistin resistance (mcr-1) by duodenoscope. Clin Infect Dis 2019;68:1327–34. CrossRef PubMed
- Food and Drug Administration. Bacterial risk control strategies for blood collection establishments and transfusion services to enhance the safety and availability of platelets for transfusion. Silver Spring, MD: US Department of Health and Human Services, Food and Drug Administration; 2018. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/bacterial-risk-control-strategies-blood-collection-establishments-and-transfusion-services-enhance
- Eder AF, Dy BA, DeMerse B, et al. Apheresis technology correlates with bacterial contamination of platelets and reported septic transfusion reactions. Transfusion 2017;57:2969–76. CrossRef PubMed
- Wong D, Nielsen TB, Bonomo RA, Pantapalangkoor P, Luna B, Spellberg B. Clinical and pathophysiological overview of Acinetobacter infections: a century of challenges. Clin Microbiol Rev 2017;30:409–47. CrossRef PubMed
- Brecher ME, Hay SN. Bacterial contamination of blood components. Clin Microbiol Rev 2005;18:195–204. CrossRef PubMed
- Becker K, Heilmann C, Peters G. Coagulase-negative Staphylococci. Clin Microbiol Rev 2014;27:870–926. CrossRef PubMed
- Levy JH, Neal MD, Herman JH. Bacterial contamination of platelets for transfusion: strategies for prevention. Crit Care 2018;22:271. CrossRef PubMed
- Heltberg O, Skov F, Gerner-Smidt P, et al. Nosocomial epidemic of Serratia marcescens septicemia ascribed to contaminated blood transfusion bags. Transfusion 1993;33:221–7. CrossRef PubMed
FIGURE. Timeline of four cases of sepsis attributed to bacterial contamination of platelets — California, Utah, Massachusetts, and Connecticut, 2018
Abbreviations: ACBC = Acinetobacter calcoaceticus-baumannii complex; ICU = intensive care unit; S. saprophyticus = Staphylococcus saprophyticus.
Suggested citation for this article: Jones SA, Jones JM, Leung V, et al. Sepsis Attributed to Bacterial Contamination of Platelets Associated with a Potential Common Source — Multiple States, 2018. MMWR Morb Mortal Wkly Rep 2019;68:519–523. DOI: http://dx.doi.org/10.15585/mmwr.mm6823a2.
MMWR and Morbidity and Mortality Weekly Report are service marks of the U.S. Department of Health and Human Services.
Use of trade names and commercial sources is for identification only and does not imply endorsement by the U.S. Department of
Health and Human Services.
References to non-CDC sites on the Internet are
provided as a service to MMWR readers and do not constitute or imply
endorsement of these organizations or their programs by CDC or the U.S.
Department of Health and Human Services. CDC is not responsible for the content
of pages found at these sites. URL addresses listed in MMWR were current as of
the date of publication.
All HTML versions of MMWR articles are generated from final proofs through an automated process. This conversion might result in character translation or format errors in the HTML version. Users are referred to the electronic PDF version (https://www.cdc.gov/mmwr) and/or the original MMWR paper copy for printable versions of official text, figures, and tables.
Questions or messages regarding errors in formatting should be addressed to mmwrq@cdc.gov.