NIOSH logo and tagline

Oil and Gas Delivery Driver Crushed Between a Dozer and a Semi-truck While Connecting Towline – West Virginia

NIOSH FACE Report 2015-01
April 18, 2018

SUMMARY

On July 3, 2013, a 24-year-old oil and gas delivery truck driver was fatally injured when he was crushed between a dozer and the front of his semi-truck. The driver was delivering concrete to the job site and, due to the hilly terrain, needed a tow to the well site. The towing dozer operator backed to the front of the driver’s semi-truck. The driver exited his cab to connect to the dozer’s towline. The driver was attempting to connect the towline to the front of his truck, but he needed a D-ring to complete the connection. The dozer operator got up from his seat and was exiting the dozer to hand the driver a D-ring. When exiting the dozer, it is believed his foot hit the parking brake lever and the dozer rolled backward, crushing the driver between the two vehicles. Emergency medical services (EMS) was called, and CPR was administered by another dozer operator until EMS arrived on-scene. The EMS responders pronounced the delivery truck driver dead shortly after their arrival. The medical examiner determined the cause of death was thoracic injuries.

CONTRIBUTING FACTORS

Occupational injuries and fatalities are often the result of one or more contributing factors or key events in a larger sequence of events that ultimately result in the injury or fatality. NIOSH investigators identified the following unrecognized hazards as key contributing factors in this incident:

  • Lack of safety training or standard operating procedure for towing vehicles
  • Lack of appropriate safeguards for equipment
  • Lack of spotter or designated hookup personnel
  • Steep terrain
  • Short length of chain being used; winch cable and chain not spooled out
  • Truck not properly equipped ahead of time for towing (i.e., no D-ring pre-mounted on hitch pin)

RECOMMENDATIONS

NIOSH investigators concluded that, to help prevent similar occurrences, employers should:

  • Ensure employees follow safe operating procedures as written in the equipment’s operations manual.
  • Implement standard operating procedures for equipment operations such as parking and towing.
  • Use a job hazard analysis (JHA) to identify and eliminate towing hazards.
  • Ensure vehicles are properly equipped for towing prior to initiating the towing connection procedures (either have a D-ring pre-mounted on the truck’s hitch pin or have a D-ring in the truck).
  • When possible, ensure a designated area is flat prior to making towing connections.
  • Dozer equipment manufacturers should consider providing an engineering control, such as an interlock or other safe guards, to prevent parking brake levers from disengaging.

 

Oil and Gas Delivery Driver Crushed Between a Dozer and a Semi-truck While Connecting Towline—West Virginia [PDF 1,297KB] Report Visual Extension [995 KB]

 

The National Institute for Occupational Safety and Health (NIOSH), an institute within the Centers for Disease Control and Prevention (CDC), is the federal agency responsible for conducting research and making recommendations for the prevention of work-related injury and illness. In 1982, NIOSH initiated the Fatality Assessment and Control Evaluation (FACE) Program. FACE examines the circumstances of targeted causes of traumatic occupational fatalities so that safety professionals, researchers, employers, trainers, and workers can learn from these incidents. The primary goal of these investigations is for NIOSH to make recommendations to prevent similar occurrences. These NIOSH investigations are intended to reduce or prevent occupational deaths and are completely separate from the rulemaking, enforcement and inspection activities of any other federal or state agency. Under the FACE program, NIOSH investigators interview persons with knowledge of the incident and review available records to develop a description of the conditions and circumstances leading to the deaths in order to provide a context for the agency’s recommendations. The NIOSH summary of these conditions and circumstances in its reports is not intended as a legal statement of facts. This summary, as well as the conclusions and recommendations made by NIOSH, should not be used for the purpose of litigation or the adjudication of any claim. For further information, visit the program website at www.cdc.gov/niosh/face/ or call toll free at 1-800-CDC-INFO (1-800-232-4636).